Search
 
 
  Home > Solutions > Infrared Thermography > FLIR > A Series > Thermovision™ A20-M
 
FLIR
thermovision™ a20-M

Compact infrared camera with temperature measurement capabilities for industrial automation.
Infrared vision systems are used worldwide in a variety of industries to monitor continuous processes. Infrared can easily detect thermal information on product quality and/or production efficiency that is difficult or impossible to capture using conventional means such as thermocouples or visible light cameras.

The ThermoVision A20-M is an affordable and accurate temperature measurement system. It is the ideal choice for industrial and automation applications requiring accurate non-contact temperature measurement.

Precision Non-Contact Temperature Measurement and Excellent Image Quality
The ThermoVision A20-M has a temperature sensitivity of 0,10 in a range from -20°C up to +900°C. It produces crisp high-resolution images (160 x 120 pixels) offering more than 19,000 individual measurement points per image at a refresh rate of 50/60 Hz.

Extensive Connectivity Options Firewire or Ethernet
The A20-M features a choice of connectivity options. For fast image and data transfer of real-time fully radiometric 16-bit images, you can choose for an IEEE-1394 FireWire digital output.

For network and/or multiple camera installations, Ethernet connectivity is available. Each A20-M can be equipped with its own unique URL allowing it to be addressed independently via its Ethernet connection. It allows controlling all menu systems of the camera and provides instant access to A20-M thermal images for any authorized user with a web browser. Images are streamed in semi realtime.

Input / Output Functionality
Fully configured I/O functionality allows the A20-M either to be integrated quickly and easily in your control systems or to be set up as a stand-alone system. The operator can set and modify up to 4 areas in the camera’s field of view. If, for example, the temperature within one of these areas rises above or falls below a predefined value, an alarm will go off.

Ultra Compact, Rugged and Lightweight
Its compact and ultra-light design allows the A20-M to be mounted in hard-to-get-at locations in your production line.

Easy Operation : Plug and Play
Simply connect the camera to a PC or a monitor and produce high-quality real-time radiometric images. The camera can be fully controlled either from the PC or with the integrated keyboard.

Integrated Keyboard
For those applications where the infrared camera and the PC are a distance away from each other, the ThermoVision A20-M has an integrated keyboard. With a few buttons, conveniently placed at the top of the camera, you can control all features.

Multiple Programming Options
The A20-M calibrated measurement output can be easily used to control a process. No need for months of programming. For application developers FLIR Systems offers two software components. A ThermoVision SDK-kit for Visual Basic / C++ programmers and a ThermoVision LabView™ Toolkit for those familiar with National Instruments LabView. Both software kits are based on ActiveX technology.

 




Affordable, fully intergrated thermal measurement solution


Precision non-contact temperatre measurement

 

High-quality thermal images

 


Maintenance-free uncooled microbolometer detector

 

Rugged and compact

 
 

Available version :

  • Firewire (IEEE-1394) : 16-bit image output and control
  • Ethernet : 8-bit image output (RTP) and control (TCP/IP)
 


ThermoVision™ A20-M includes:

  • IR camera
  • Power supply including cable
  • Fireqire cable (Firewire version only)
  • Configuration CD
  • Lens cap
  • Manual
 
Imaging Performance
Field of view/min focus distance
Spatial resolution (IFOV)
Thermal sensitivity
Focusing
Detector type
Spectral range
Typical 19° x 14°/0.3 m (with 17 mm lens)
2.1 mrad
0.10°C at 30°C
Manual
Focal Plane Array (FPA), uncooled microbolometer
7.5 to 13 µm
 

Image Presentation

Image Output

RS170 EIA/NTSC or CCIR/PAL analog composite video and FireWire (IEEE-1394) 8-/16-bit digital image output or Ethernet 8-bit digital output (RTP)

   
Measurement
Temperature ranges

Accuracy
Measurement modes
Emissivity corrections
Reflected ambient temperature correction
External optics / window correction

-20°C to +250°C (-4°F to +482°F)
to +900°C (+1652°F) (optional)
± 2°C, ± 2% of reading
Spot, area, isotherm, Delta T, iso-coverage
Variable from 0.1 to 1.0
Automatic, based on input of reflected temperature

Automatic, based on input of optics/window transmission and temperature

   
Lenses (Optional)
2 x Telescope
0.5 Wide angle
0.25 Wide angle
Typical 9° x 7°/1.2 m (with 36 mm lens)
Typical 34° x 25°/0.1 m (with 9 mm lens)
Typical 60 x 45°/0.1 m (with 4.5 mm lens)
   
Power Source
AC operation
Voltage
AC adapter 110/220 V AC, 50/60 Hz
12/24 V nominal, < 6 W
   
Environmental Specifications
Operating temperature range
Storage temperature range
Humidity
Encapsulation
Shock
Vibration
-15°C to +55°C (+5°F to +122°F)
-40°C to +70°C (-40°F to +158°F)
Operating and storage 10% to 95%, non condensing
IP 40 (determined by connector type)
Operational: 25G, IEC 68-2-29
Operational: 2G, IEC 68-2-6
   
Physical Characteristics
Weight
Size

Tripod Mounting

0.8 kg (1.7 lbs)
157 mm x 75 mm x 80 mm
(6.2" x 2.9" x 3.1")
1/4" - 20

   
Interfaces
Digital image output
and camera control 16-bit


BNC
6-pin screw terminal (upper)

6-pin screw terminal (lower)
6-pin FireWire (IEEE-1394) connector handling iso-chronous digital image data and asynchronous control data or standard RJ-45 Ethernet connector handling image data (RTP) and control data (TCP/IP)
Composite video (NTSC/PAL)
Digital I/O: 3 Output - 1 Input
1 Input/Output selectable. User configurable*
Analog I/O: 2 Output - 1 Input,
User configurable* - see user configuration table
   

User Configuration Table*

Type Function Remark
Digital input TTL Level: Shutter disable, Store image, Batch enable Isolation and relay function in external module
Digital output TTL Level: Spot / Area threshold alarm,
Internal temperature sensor alarm, V-sync
Isolation and relay function in external module
Analog output Spot / Area out 0 - 5 V, Internal temperature sensor out 0 - 5 V Scaled to Tlow - Thigh Isolation in external module
Analog input External temperature sensor in 0 - 10 V Scaled to Tlow - Thigh Isolation in external module
 